Description

TeSys Deca contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys Deca contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 95A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.55 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Features

  • Rated for 95 Amps under AC-3 utilization categories ($45\text{ kW}$ at $380/400\text{V}$), this TeSys Deca contactor is purpose-built for demanding, high-inrush motor control applications. It ensures reliable, repetitive starting and stopping of heavy industrial equipment like large ventilation fans, industrial compressors, and high-capacity centrifugal pumps without contact welding.
  • Equipped with a standard 120V AC coil (G7 voltage code) operating at both 50Hz and 60Hz, this contactor seamlessly drops into standard plant control topologies. It eliminates the need for auxiliary control transformers, allowing direct connection to standard control transformers, timing relays, and push-button stations commonly deployed across commercial and industrial facilities.
  • Outfitted with integrated, mechanically linked auxiliary contacts (1 Normally Open + Normally Closed) the device provides instant, real-time feedback to PLCs, pilot lights, or secondary safety circuits. The dual-contact architecture allows panel builders to configure hardwired electrical cross-interlocking between forward/reversing contactor pairs or star-delta starters out of the box, saving valuable DIN rail space.
  • Boasting robust electrical endurance and high breaking capacity, this contactor coordinates perfectly with Schneider s TeSys Overload Relays and circuit breakers to achieve Type 2 coordination. This ensures that even after a severe short-circuit or overcurrent event, the contactor sustains minimal damage, preventing catastrophic panel fires and drastically reducing post-fault restoration costs.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, Costa Rica, Czechia, France, United States
Depth130 mm

Complementary Attributes

Control Circuit Voltage Limits
0.8...1.1 Uc (-40-55 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-55 °C):operational AC 60 Hz, 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 1...1.1 Uc (55-70 °C):operational AC 50/60 Hz
Maximum Horse Power Rating
30 hp at 230/240 V AC 60 Hz for 3 phase motors7.5 hp at 120 V AC 60 Hz for 1 phase motors, 15 hp at 230/240 V AC 60 Hz for 1 phase motors, 30 hp at 200/208 V AC 60 Hz for 3 phase motors, 60 hp at 460/480 V AC 60 Hz for 3 phase motors, 60 hp at 575/600 V AC 60 Hz for 3 phase motors
Maximum Motor Phase Current
95 A
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
1100 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity1100 A at 440 V AC for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Control Circuit TypeAC 50/60 Hz
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1, 200 A gG at <= 690 V coordination type 1 for power circuit, 160 A gG at <= 690 V coordination type 2 for power circuit
Electrical Durability
1.2 Mcycles 95 A AC-3, 1.3 Mcycles 125 A AC-1, 1.2 Mcycles 95 A AC-3e
Insulation Resistance
> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw
45 kW at 380...400 V AC 50 Hz (AC-3e), 45 kW at 415...440 V AC 50 Hz (AC-3e), 55 kW at 500 V AC 50 Hz (AC-3e), 45 kW at 660...690 V AC 50 Hz (AC-3e)25 kW at 220...230 V AC 50 Hz (AC-3), 45 kW at 380...400 V AC 50 Hz (AC-3), 45 kW at 415...440 V AC 50 Hz (AC-3), 55 kW at 500 V AC 50 Hz (AC-3), 45 kW at 660...690 V AC 50 Hz (AC-3), 15 kW at 400 V AC 50 Hz (AC-4), 25 kW at 220...230 V AC 50 Hz (AC-3e)
Operating Time
20...35 ms closing, 6...20 ms opening
Safety Reliability Level
B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1, B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Utilisation Category
AC-3, AC-3e, AC-4, AC-1
[Icw] Rated Short-time Withstand Current
1100 A 40 °C - 1 s for power circuit, 800 A 40 °C - 10 s for power circuit, 400 A 40 °C - 1 min for power circuit, 135 A 40 °C - 10 min for power circuit, 140 A - 100 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 100 A - 1 s for signalling circuit
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C) for signalling circuit, 125 A (at 60 °C) for power circuit
[Ui] Rated Insulation Voltage
signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 1000 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1
Hold-in Power Consumption In Va
26-26 VA 60 Hz cos phi 0.3 (at 20 °C), 26-26 VA 50 Hz cos phi 0.3 (at 20 °C)
Carbon Footprint Of The Distribution Phase [A4]
0.2186857202937272, 0.2 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]
0.3 kg CO2 eq., 0.31355370764190865
Carbon Footprint Of The Use Phase [B2, B3, B4, B6]
90 kg CO2 eq., 90.13463768115939
Local Publishable Date
2026-03-25
Stocking Flag
N
Device Type
LV equipment - LV contactor
Traceability
No
Average Life Duration
20 year(s)
Weee Product Category
5
Eoli Availability Display
No need of specific recycling operations
Reach Full Compliance Status Id
NOT_CONTAINING_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Conformity Date
1924
China Rohs In Scope
No
With Recycled Cardboard
Yes
Product Contributes To Saved And Avoided Emissions
No
Tier
1
Function Option
Standard
Average Impedance
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Compatibility Code
LC1D
Device Short Name
LC1D
Flame Retardance
V1 conforming to UL 94
Mechanical Durability
4 Mcycles
Overvoltage Category
III
Product Availability
Stock - Normally stocked in distribution facility
Protective Treatment
THIEC 60068-2-30
Range Of Product
TeSys Deca
Signalling Circuit Frequency
25...400 Hz
Sustainable Packaging
Yes
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Inf Motor Phase Current
95 A
Database Version
2022-01
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Functional-unit Description
Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3P(3NO), a control circuit voltage 230V AC, a power circuit voltage 690V and a rated operational current 80A
Functional-unit Unit
unit
Energy Consumption On Product Lifetime, In Kwh
1349.04
Energy Model - Installation [A5]
Electricity Mix; Production mix; Low voltage; FR
Energy Model - End Of Life [C1-c4]
Electricity Mix; Production mix; Low voltage; FR
Height Nominal
127 mm
[Ue] Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hz
Nbr. Of Units In Pkg.
1
Take-back
No
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Applicationresistive load, motor control
Inrush Power In Va245-245 VA 60 Hz cos phi 0.75 (at 20 °C), 245-245 VA 50 Hz cos phi 0.75 (at 20 °C)
Mechanical Robustnessvibrations contactor open 2 Gn, 5...300 Hz), shocks contactor open 8 Gn for 11 ms), vibrations contactor closed 3 Gn, 5...300 Hz), shocks contactor closed 10 Gn for 11 ms)
Mounting Supportplate, rail
Power Dissipation Per Pole12.5 W AC-1, 7.2 W AC-3, 7.2 W AC-3e
Tightening Torquecontrol circuit 1.2 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.2 N.m screw clamp terminals Philips No 2, power circuit 12 N.m connector flat Ø 6 to Ø 8 mm, power circuit 12 N.m connector hexagonal 4 mm, control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Certificate AgencyCCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC
[Ie] Rated Operational Current95 A (at <60 °C) at <= 440 V AC-3 for power circuit, 125 A (at <60 °C) at <= 1000 V AC-1 for power circuit, 95 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] Control Circuit Voltage120 V, 120 V AC 50/60 Hz
Connections - Terminalscontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 4-50 mm² - cable stiffness: solid without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: solid without cable end, screw clamp terminals, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end
Non-overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End-of-life Phase [C1 To C4]4.135516392561003, 4 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]11 kg CO2 eq., 11.08540862132033
Local Data StatusPublishable
Return IndicatorY
Stock Policy2
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Coil Technologywithout built-in suppressor module
Contact CompatibilityM11
Fire Resistance850 °C IEC 60695-2-1
Heat Dissipation6-10 W at 50/60 Hz
Number Of Poles3P
Pole Contact Composition3 NO
Product Or Component Typecontactor
RangeTeSys
ReturnabilityYes
Software Versionv5.9.4
Total Lifecycle Carbon Footprint106 kg CO2 eq.
Control Circuit Voltage120 V
Pep CodeENVPEP1102005EN
Pep Verification Date2025-08-05
Psr VersionPSR-0005-ed2-2016 03 29
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime, In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Production mix; Low voltage; CZ
Energy Model - Use [B6]Electricity Mix; Production mix; Low voltage; FR
Recyclability Potential, In %76
Width Nominal85 mm
[Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947
Package Weight(Lbs)1.600 kg
Warranty (In Months)18

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Take Back
No
Recycled Metal Content At Cr Level
0 %
Mercury Free
Yes
Climatic Withstand
IACS E10 exposure to damp heat
Eu Rohs Directive
Compliant
Operating Altitude
0...9842.52 ft (0...3000 m)
Packaging Without Single Use Plastic
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Pep Verification Date
2025-08-05
Psr Version
PSR-0005-ed2-2016 03 29
Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C, 60-70 °C with derating
Reach Free ShvcYes
Toxic Heavy Metal FreeYes
Carbon Footprint105.88780212297635
Environmental DisclosureENVPEP1102005EN
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Reach Free Of SvhcYes
Pep CodeENVPEP1102005EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys Deca

ETIM

ETIM 8
EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months
Loading video…

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$717.54/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!

",{"children":null,"id":"ahrefs web analytics"}])",{"children":null,"id":"ahrefs web analytics"}])